adafruit_scd30
¶
Helper library for the SCD30 CO2 sensor
Author(s): Bryan Siepert
Implementation Notes¶
Hardware:
Software and Dependencies:
Adafruit CircuitPython firmware for the supported boards: https://github.com/adafruit/circuitpython/releases
Adafruit’s Bus Device library: https://github.com/adafruit/Adafruit_CircuitPython_BusDevice
Adafruit’s Register library: https://github.com/adafruit/Adafruit_CircuitPython_Register
- class adafruit_scd30.SCD30(i2c_bus, ambient_pressure=0, address=97)¶
CircuitPython helper class for using the SCD30 CO2 sensor
- Parameters
Quickstart: Importing and using the SCD30
Here is an example of using the
SCD30
class. First you will need to import the libraries to use the sensorimport board import adafruit_scd30
Once this is done you can define your
board.I2C
object and define your sensor objecti2c = board.I2C() # uses board.SCL and board.SDA scd = adafruit_scd30.SCD30(i2c)
Now you have access to the CO2, temperature and humidity using the
CO2
,temperature
andrelative_humidity
attributestemperature = scd.temperature relative_humidity = scd.relative_humidity co2_ppm_level = scd.CO2
- property CO2¶
Returns the CO2 concentration in PPM (parts per million)
Note
Between measurements, the most recent reading will be cached and returned.
- property altitude¶
Specifies the altitude at the measurement location in meters above sea level. Setting this value adjusts the CO2 measurement calculations to account for the air pressure’s effect on readings.
Note
This value will be saved and will not be reset on boot or by calling
reset
.
- property ambient_pressure¶
Specifies the ambient air pressure at the measurement location in mBar. Setting this value adjusts the CO2 measurement calculations to account for the air pressure’s effect on readings. Values must be in mBar, from 700 to 1400 mBar
- property data_available¶
Check the sensor to see if new data is available
- property forced_recalibration_reference¶
Specifies the concentration of a reference source of CO2 placed in close proximity to the sensor. The value must be from 400 to 2000 ppm.
Note
Specifying a forced recalibration reference will override any calibration values set by Automatic Self Calibration
- property measurement_interval¶
Sets the interval between readings in seconds. The interval value must be from 2-1800
Note
This value will be saved and will not be reset on boot or by calling
reset
.
- property relative_humidity¶
Returns the current relative humidity in %rH.
Note
Between measurements, the most recent reading will be cached and returned.
- reset()¶
Perform a soft reset on the sensor, restoring default values
- property self_calibration_enabled¶
Enables or disables automatic self calibration (ASC). To work correctly, the sensor must be on and active for 7 days after enabling ASC, and exposed to fresh air for at least 1 hour per day. Consult the manufacturer’s documentation for more information.
Note
Enabling self calibration will override any values set by specifying a
forced_recalibration_reference
Note
This value will be saved and will not be reset on boot or by calling
reset
.
- property temperature¶
Returns the current temperature in degrees Celsius
Note
Between measurements, the most recent reading will be cached and returned.
- property temperature_offset¶
Specifies the offset to be added to the reported measurements to account for a bias in the measured signal. Value is in degrees Celsius with a resolution of 0.01 degrees and a maximum value of 655.35 C
Note
This value will be saved and will not be reset on boot or by calling
reset
.